Explosives Detection Standard
For teams that search buildings, vehicles, packages and venues for explosives. Structured on ANSI/ASB Standard 092, and applies together with the common requirements.
Odor classes
The core certification tests the six classes below. Each test includes at least five of them, chosen by the hide setter, so the team must be proficient in all six.
| Class | Examples | Standard amount per hide |
|---|---|---|
| 1. Propellants | Smokeless powder, black powder | 1–4 oz (28–113 g) |
| 2. Nitroglycerin-based | Dynamite | ¼–1 lb (113–454 g) |
| 3. Nitroaromatic | TNT | ¼–1 lb (113–454 g) |
| 4. Nitramine plastic explosives | C-4 and other RDX-based compositions | ¼–1 lb (113–454 g) |
| 5. Nitrate esters | Detonating cord and sheet explosives (PETN-based) | 2–6 ft (0.6–1.8 m) of cord, or equivalent |
| 6. Ammonium nitrate-based | ANFO, water gels, emulsions | ¼–1 lb (113–454 g) |
- Small-source hide: at least one hide in each test is at the low end of its class's range.
- Distractors: at least 4 in each test, including potting soil, motor oil, plastic wrap, food and a common personal item.
- Licensing: all explosive aids are supplied, stored and transported by the Council under its ATF federal explosives license and kept in approved magazines. No initiators or detonators are ever present.
Homemade-explosives (HME) endorsement (optional)
Tests recognition of oxidizers and improvised compositions: potassium chlorate and perchlorate mixtures, urea nitrate, and peroxide-based explosives (TATP and HMTD). Peroxide-based and other unstable compositions are tested only with validated non-hazardous training aids.
Search phases
| Phase | Setting | Areas | Aids | Blanks | Time limit |
|---|---|---|---|---|---|
| 1. Interior | Offices, classrooms, hallways, rooms set up like patient rooms | 3 rooms | 2–3 | At least 1 room | 15 min total |
| 2. Vehicles | Cars, trucks or vans, exterior | 4 vehicles | 1–2 | At least 2 | 12 min total |
| 3. Luggage and packages | A line of bags, boxes or parcels | 12 items | 1–2 | At least 9 | 10 min |
| 4. Open area | A lobby, concourse, loading dock or parking area, about 2,500 sq ft (230 m²) | 1 area | 1–2 | — | 10 min |
Across the four phases, a test holds at least 6 aids covering at least five odor classes.
Pass criteria
- Every aid found. In explosives detection, a single miss fails the test.
- No more than 1 false alert across all phases
- Passive final response on every find
- No automatic failure
People-screening endorsement (optional)
For teams that screen people at entrances and in crowds for person-borne explosives. At least 12 adult volunteers take part, each of whom signs a consent form. Two to four carry a sealed, non-hazardous explosive odor aid. The team screens them in a lineup and then as they move through an entrance or concourse. To pass, the team must find every carrier in both runs with no more than 1 false alert, and the dog must not touch anyone.